Tel:0510-86199028
-
E-mail:info@sfere-elec.com
-
Add:No.1 Dongding Road, Jiangyin, Jiangsu, China
All-in-One 10-ft Container
Highly integrated 3S system, cooling system, and fire protection system, delivering greater capacity within a smaller footprint.
String-Based Solution
Each battery cluster is independently managed, enhancing system reliability and stability.
On/off-grid Switching
<20ms seamless on/off-grid switching function is an available optional feature, for special requirement.
Multiple Power Source Options
Equipped with reserved interfaces for diesel generator and PV inverter, the system supports multiple power sources, making it suitable for a wide range of application scenarios.
| DC Side | ECO-E10FT1044LP-2-N | ECO-E10FT1044LP-2-S |
| Cell Type | LFP / 314 Ah | LFP / 314 Ah |
| Pack Configuration | 52.2 kWh / IP52S | 52.2 kWh / IP52S |
| System Configuration | 1044 kWh / 4P260S | 1044 kWh / 4P260S |
| Rated DC Voltage | 832 V | 832 V |
| DC Voltage Range | 728 ~ 936 V | 728 ~ 936 V |
| Max. Charge/Discharge Rate | 0.5 P | 0.5 P |
| Max. Depth of Discharge | 100% (25 ± 2 °C) | 100% (25 ± 2 °C) |
| Power Source | ||
| Rated ESS Power | 500 kW | 500 kW |
| Rated AC Voltage | 400 V | 400 V |
| AC Voltage Range | ±15% | ±15% |
| Grid Type | 3W+N+PE | 3W+N+PE |
| Rated Frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Rated STS Power | / | 1000kW |
| On/Off-grid Switching | / | <20ms |
| Power Factor | 0.99 (1 leading - 1 lagging) | 0.99 (1 leading - 1 lagging) |
| THDi | ≤3% | ≤3% |
| DC Ratio | <0.5% Ipn | <0.5% Ipn |
| Max. PV Inverter Input Current | / | 800 A |
| Max. Diesel Generator Input Current | / | 800 A |
| AC Side | ||
| Max. Backup Load Port Current | 800 A | 800 A |
| Max. Backup Load Power* | 350kW (70% of Rated Output Power) | 350kW (70% of Rated Output Power) |
General | ||
| Max. Round Trip Efficiency | 88% | 87% |
| Cycle Life | ≥ 8,000 cycles | ≥ 8,000 cycles |
| Communication | Modbus TCP | Modbus TCP |
| Fire Suppression System | Aerosol system+Water spray system | Aerosol system+Water spray system |
| Ingress Rating | IP55 | IP55 |
| Cooling | Liquid cooling+Forced air cooling | Liquid cooling+Forced air cooling |
| Operating Temperature | -25°C~55°C (Derating after 45°C) | -25°C~55°C (Derating after 45°C) |
| Anticorrosion Rating | C4 (C5 optional) | C4 (C5 optional) |
| Humidity | 0~95% RH (non-condensing) | 0~95% RH (non-condensing) |
| Noise | ≤ 80 dB | ≤ 80 dB |
| Altitude | 3000m (Derating above 2000m) | 3000m (Derating above 2000m) |
| Dimensions (WDH) | 299124382591 mm | 299124382591 mm |
| Weight | 14 t | 14 t |
| Safety/EMC | UN3536, IEC62477-1, IEC62619, IEC63056, IEC61000-6-2/4, UL9540A | UN3536, IEC62477-1, IEC62619, IEC63056, IEC61000-6-2/4, UL9540A |
| Grid code | EN50549-1/-10, EN50549-2/-10, G99, VDE4105, NRS097, C10/11 | EN50549-1/-10, EN50549-2/-10, G99, VDE4105, NRS097, C10/11 |